17 Ago ICM282B – Control Board for Carrier Boards HK42FZ004/007/008/009/011/013/016/034
Replaces Carrier: CEBD431012-01A, CEPL131012-01, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034 and 325878-751....
Replaces Carrier: CEBD431012-01A, CEPL131012-01, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034 and 325878-751....
FEATURES: Engineered for reliability and safety, this board provides 100% gas shutoff in case of ignition failure. ELECTRICAL SPECIFICATIONS: This board operates within a 98-132 VAC range and is rated for critical components: ignitor (5A/120V), cool blower (30A/2HP/240V), heat blower (5A/240V), inducer motor (4A/120V), and...
INSTALLATION NOTES: Before removal, take a clear photo of your old board's wiring for a hassle-free installation reference. It ensures your furnace runs smoothly and efficiently by coordinating all key components....