Endress & Hauser FTI51 Liquicap M Level Probe FT151-ABB1GGJ32A1A 250mm - JIMFRA
224984
wp-singular,itempress_product-template-default,single,single-itempress_product,postid-224984,wp-theme-jimfra,ajax_fade,page_not_loaded,,qode-theme-ver-9.0,wpb-js-composer js-comp-ver-4.11.1,vc_responsive,itempress-page
Endress & Hauser FTI51 Liquicap M Level Probe FT151-ABB1GGJ32A1A 250mm

Endress & Hauser FTI51 Liquicap M Level Probe FT151-ABB1GGJ32A1A 250mm

USD 200.00 USD
SKU: peIEO6I7
Condition: Used

Specifications

All Returns AcceptedReturnsNotAccepted
BrandEndress & Hauser
MPNFTI51-AAH1RCJ43D1A
Country/Region Of ManufactureUnited States

Field of applicationLiquicap FTI51 is a rod probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI51 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.Process connections: Flanges, threads, special hygienic process connectionsTemperature: -80 to +200°C (-112 to +392°F)Pressure: Vacuum to +100bar (vacuum to +1,450psi)Sensor length: 6m (20ft)International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvalBenefitsCost savings thanks to easy and fast commissioning as calibration takes place at the press of a buttonReliable and safe measurement due to active build-up compensationReliable and universal application thanks to wide range of certificates and approvalsShort reaction timeMaterial in contact with the process made of corrosion-resistant and FDA-listed materialsTwo-stage overvoltage protectionNo need for recalibration after replacing electronics Required010Approval:ANon-hazardous area020Inactive Length L3:B Not selected + active build-up protection 125mm/5in, 316L030Active Probe Length L1; Insulation:B250..... mm, 16mm rod, 316L; PTFE10040Insulation:1Fully insulated050Process Connection:GGJThread ISO228 G1-1/2, 316L, 100bar060Electronics; Output:3FEI53; 3-wire 3-12V signal070Housing:2F16 Polyester IP66/67 NEMA4X080Cable Entry:A thread M20)" style="font-size: 0.875em;">Gland M20 (EEx d > thread M20)090Type of Probe:1Compact100Additional Option:ABasic versionOptional

Related Items